The field in the middle shows a list of all the functions and parameters that will be executed during a measurement.
You can choose any of the items in the list that opens when you click the Add button. The selected item will be added to the script.
Modify can be used to edit an existing script.
Delete deletes the selected entry row.
Move Up moves the selected entry row up by one row in the script.
Move Down moves the selected entry row down by one row in the script.
Insert Script can be used to insert the contents of another script file into the current script.
Repeat Script value defines how many times the script will be repeated during the measurements. The range of repeat script values is from 1 to 10,000.
Use device settings for script commands option
New clears the entry fields for inserting new script values.
Open opens a dialog box for selecting an existing script file to be modified or reviewed.
Save saves the file with the existing name or if the script is a new one, opens a dialog box for inserting the file name.
Save As opens a dialog box for inserting a new file name.
Close exits the dialog box.